Views: 0 | Downloads: 0
Human cytomegalovirus (HCMV) is a ubiquitous and latent human virus that is transmitted by body fluids and causes severe morbidity and mortality in transplant patients, neonates and AIDS-infected patients. Pre-emptive treatment of HCMV-infected transplant patients is based on monitoring viral kinetics and is followed by prompt changes in antiviral administration, hence it diminishes harmful effects of toxic antivirotics, reduces treatment cost and decreases the risk for antivirotic resistance. Molecular methods, such as real-time PCR (qPCR) and digital PCR (dPCR), allow for sensitive quantification of virus-DNA copies and are important tools for monitoring of viral load. Since reliable clinical diagnosis depends greatly on the comprehensive knowledge on performance parameters of DNA extraction, qPCR and dPCR, more information is required to better characterize these methods and thus improve reliability of clinical measurements. Additionally, the establishment of metrological framework for nucleic-acid tests is expected to increase the degree of standardisation of qPCR-based clinical measurements between laboratories, with dPCR as a promising candidate for a reference measurement procedure and for characterization of certified reference materials (CRMs). In this work, two metrological assessments were conducted to extend the knowledge on performance parameters of methods for manual HCMV DNA extraction (kits from Roche, Cepheid and Qiagen) and for quantification of HCMV DNA (qPCR, droplet-based and chip-based dPCR). Additionally, inter-laboratory study was performed to assess the reproducibility of dPCR for quantification of HCMV, while its suitability for direct quantification of HCMV without DNA extraction was also investigated. Each metrological study has improved the knowledge on processes involved in DNA extraction and DNA quantification. Broadened information on analytical parameters, such as DNA recovery (DNA extraction methods), precision (DNA extraction and quantification methods), analytical sensitivity, linearity of dynamic range and robustness (quantification approaches), has better defined the contribution of each method to measurement variability and bias. DNA extraction methods from Roche and Qiagen, and qPCR were shown as more suitable for routine clinical testing than others, as they are more repeatable in quantification of clinically important concentrations of virus in body fluids. In contrast to qPCR, dPCR demonstrated higher reproducibility, accuracy and robustness with higher DNA concentrations and appears suitable candidate for implementation in metrological framework. Additionally, direct quantification by dPCR provided less variable and more accurate measurements of DNA concentration than quantification of extracted DNA, and could enable a more accurate characterization of CRM for viruses.